The Brace
The Column
The Patent
Load Tables
Installation
Images
Contact us


  Load Tables
 
POWERTRUSS COLUMN
BRACING + DOWNLOAD
ENGINEER CERTIFIED


350mm POWERTRUSS COLUMN
ULTIMATE LIMIT STATE LOAD

COLUMN SIZE
LATERAL BRACING
FLOOR AND ROOF LOAD
HEIGHT
WIDTH
DEPTH
REGION “A”
REGION “B, C &D”
ALL REGIONS
2140
350
75
4.5kN
6.5kN
60kN
2440
350
75
4.3kN
6.1kN
60kN
2740
350
75
4.1kN
5.7kN
60kN

450mm POWERTRUSS COLUMN
ULTIMATE LIMIT STATE LOAD

COLUMN SIZE
LATERAL BRACING
FLOOR AND ROOF LOAD
HEIGHT
WIDTH
DEPTH
REGION “A”
REGION “B, C &D”
ALL REGIONS
2140
450
75
6.7kN
11.3kN
60kN
2440
450
75
6.3kN
10.6kN
60kN
2740
450
75
5.9kN
10.0kN
60kN

600mm POWERTRUSS COLUMN
ULTIMATE LIMIT STATE LOAD

COLUMN SIZE
LATERAL BRACING
FLOOR AND ROOF LOAD
HEIGHT
WIDTH
DEPTH
REGION “A”
REGION “B, C &D”
ALL REGIONS
2140
600
75
12.0kN
16.9kN
60kN
2440
600
75
11.3kN
15.9kN
60kN
2740
600
75
10.6kN
15.0kN
60kN
2940
600
75
9.6kN
13.5kN
60kN

NOTE: Height can be altered to suit your project.

 

 

 

 

 

 

 
 